![]() ![]() Cages for Fixed Ladders: The requirements for cages for fixed ladders are as follows: Horizontal bands must be fastened to the side rails of rail ladders or directly to the structure, building or equipment for individual-rung ladders. ![]() If obstructions are unavoidable, clearance may be reduced to 24 inches (61 cm), provided a deflection device is installed to guide workers around the obstruction.ฤก0. Minimum perpendicular clearance between the centerline of fixed ladder rungs, cleats and steps, and any obstruction on the climbing side of the ladder must be 30 inches (76 cm). ![]() ![]() Minimum perpendicular clearance between fixed ladder rungs, cleats, and steps and any obstruction behind the ladder must be 7 inches (18 cm), except that the clearance for an eleva- tor pit ladder must be 4.5 inches (11 cm). Rungs and steps of fixed metal ladders manufactured after March 15, 1991, must be corrugated, knurled, dimpled, coated with skid-resistant material or treated to minimize slipping. Rungs of individual rung/step ladders must be shaped to prevent slipping off the end of the rungs. Fixed Ladders: In addition, fixed ladders must meet the following requirements: Minimum clear distance between the sides of individual rung/step ladders and between the side rails of other fixed ladders must be 16 inches (41 cm). ![]()